TXLP/2 Twin Conductor Heating Cable Units

Applications:

The heating cable units are ideal for floor warming and radiant heating in concrete and wood floor constructions. They are also used in snow melting installations, frost protection of roof, gutters, drains, pipe tacing and soil heating. Each unit has a unique factory made internal splice which is marked =>SPLICE<= on the cable surface. There is no need for a return conductor. The sealed end is 100% waterproof (factory made seal). The cold end is marked with snowflakes on the cable surface.

Construction:

• Solid resistance wire
• XLPE insulation
• Tinned copper earthing conductor
• Aluminum screen
• PVC outer jacket
• Overall diameter: approx. 6.5 mm (1/4”)

Technical data:

• Element values from 300 to 3300W
• Linear load: 17 W/m
• Series resistance
• Maximum continuously operating temperature outer jacket: 65 C (149 F)
• Minimum bending radius: 5 x cable diameter
• Tolerance on conductor resistance: -5 to +10 %
• Highest system voltage: 300 - 600 V

Twin Conductor 120V Floor Warming / Radiant Heating Cable      
TYPE OUTPUT CABLE COVERAGE NOMINAL MAXIMUM WEIGHT NEXANS
AT 120V LENGTH RESISTANCE MAGNETIC PER UNIT CODE
  *    FLUX DENSITY    
(watt) (ft) (sq ft) (ohm)   (lb)  
TXLP/2R 200/17/1 200 40 7-20 72 0.29 2.3 10144813
TXLP/2R 300/17/1 300 60 21-30 48 0.48 3.4 10144844
TXLP/2R 400/17/1 400 80 31-40 36 0.67 4.3 10144846
TXLP/2R 500/17/1 500 100 41-50 29 0.96 5.3 10144847
TXLP/2R 600/17/1 600 114 51-60 24 1.19 6.3 10144848
TXLP/2R 700/17/1 700 138 61-70 21 1.32 7 10144849
TXLP/2R 850/17/1 850 164 71-85 17 1.64 8.4 10144850
                 
Twin Conductor 240V Floor Warming / Radiant Heating Cable      
TYPE OUTPUT CABLE COVERAGE NOMINAL MAXIMUM WEIGHT NEXANS
AT 240V LENGTH RESISTANCE MAGNETIC PER UNIT CODE
  *    FLUX DENSITY    
(watt) (ft) (sq ft) (ohm)   (lb)  
TXLP/2R 300/17/2 325 58 10-24 176 0.8 1.4 10022293
TXLP/2R 400/17/2 435 77 25-33 132 1.06 1.8 10022294
TXLP/2R 500/17/2 545 96 34-41 106 1.33 2.2 10022295
TXLP/2R 600/17/2 655 115 42-50 88 1.46 2.6 10022296
TXLP/2R 700/17/2 760 135 51-65 76 1.59 2.9 10022297
TXLP/2R 840/17/2 915 163 66-85 63 1.86 3.5 10022298
TXLP/2R 1000/17/2 1090 191 86-105 53 2.23 4.1 10022288
TXLP/2R 1250/17/2 1360 238 106-125 42 2.65 5 10022289
TXLP/2R 1370/17/2 1490 265 126-140 39 3.32 5.3 10022290
TXLP/2R 1700/17/2 1850 328 141-175 31 3.63 6.7 10022291
TXLP/2R 2100/17/2 2285 406 176-220 25 4.51 8.3 10022292
TXLP/2R 2600/17/2 2830 507 221-260 20 5.57 9.5 10047809
TXLP/2R 3300/17/2 3590 636 261-310 16 6.9 11.7 10022300
                 
* Plus 7.5 ft cold lead in each end

Download:

TXLP/2 Twin Conductor Cable Units Data Sheet

Go to Download Center for a complete list of installation manuals